NOAA ERDDAP
Easier access to scientific data
| ?    
Brought to you by NOAA NMFS SWFSC ERD    

ERDDAP > info > SUNA_V2

Grid
DAP
Data
Sub-
set
Table
DAP
Data
Make
A
Graph
W
M
S
Source
Data
Files
Title Sum-
mary
FGDC,
ISO,
Metadata
Back-
ground
Info
RSS E
mail
Institution Dataset ID
     data   graph     HMSCCMS : SUNA_V2    ?            M   background (external link) RSS Subscribe
Oregon State Univ...  ?
SUNA_V2

The Dataset's Variables and Attributes

Row Type Variable Name Attribute Name Data Type Value
attribute NC_GLOBAL cdm_data_type String Other
attribute NC_GLOBAL creator_name String Oregon State University
attribute NC_GLOBAL creator_url String http://ceoas.oregonstate.edu (external link)
attribute NC_GLOBAL infoUrl String http://ceoas.oregonstate.edu (external link)
attribute NC_GLOBAL institution String Oregon State University
attribute NC_GLOBAL keywords String atmosphere, data, observations, ocean, vessel
attribute NC_GLOBAL license String The data may be used and redistributed for free but is not intended
for legal use, since it may contain inaccuracies. Neither the data
Contributor, ERD, NOAA, nor the United States Government, nor any
of their employees or contractors, makes any warranty, express or
implied, including warranties of merchantability and fitness for a
particular purpose, or assumes any legal liability for the accuracy,
completeness, or usefulness, of this information.
attribute NC_GLOBAL sourceUrl String (source database)
attribute NC_GLOBAL summary String RCRV CORIOLIX
attribute NC_GLOBAL title String HMSCCMS : SUNA_V2
variable time_raw   double  
attribute time_raw ioos_category String Time
attribute time_raw long_name String Time Raw
attribute time_raw time_origin String 01-JAN-1970 00:00:00
attribute time_raw units String seconds since 1970-01-01T00:00:00Z
variable time   double  
attribute time _CoordinateAxisType String Time
attribute time axis String T
attribute time ioos_category String Time
attribute time long_name String Time
attribute time standard_name String time
attribute time time_origin String 01-JAN-1970 00:00:00
attribute time units String seconds since 1970-01-01T00:00:00Z
variable sensor_id   String  
attribute sensor_id ioos_category String Identifier
attribute sensor_id standard_name String xxxxxx
attribute sensor_id units String none
variable nitrate_concentration_processed_corrected_umol   float  
attribute nitrate_concentration_processed_corrected_umol ioos_category String Dissolved Nutrients
attribute nitrate_concentration_processed_corrected_umol sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute nitrate_concentration_processed_corrected_umol standard_name String ntrzms01
attribute nitrate_concentration_processed_corrected_umol units String umol
variable nitrate_concentration_processed_corrected_umol_flags   String  
attribute nitrate_concentration_processed_corrected_umol_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute nitrate_concentration_processed_corrected_umol_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute nitrate_concentration_processed_corrected_umol_flags ioos_category String Dissolved Nutrients
attribute nitrate_concentration_processed_corrected_umol_flags standard_name String ntrzms01_status_flag
attribute nitrate_concentration_processed_corrected_umol_flags units String none
variable nitrogen_in_nitrate_processed_corrected_mg_n_per_l   float  
attribute nitrogen_in_nitrate_processed_corrected_mg_n_per_l ioos_category String Dissolved Nutrients
attribute nitrogen_in_nitrate_processed_corrected_mg_n_per_l sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute nitrogen_in_nitrate_processed_corrected_mg_n_per_l standard_name String xxxxxxxx
attribute nitrogen_in_nitrate_processed_corrected_mg_n_per_l units String mg N/l
variable nitrogen_in_nitrate_processed_corrected_mg_n_per_l_flags   String  
attribute nitrogen_in_nitrate_processed_corrected_mg_n_per_l_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute nitrogen_in_nitrate_processed_corrected_mg_n_per_l_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute nitrogen_in_nitrate_processed_corrected_mg_n_per_l_flags ioos_category String Dissolved Nutrients
attribute nitrogen_in_nitrate_processed_corrected_mg_n_per_l_flags standard_name String xxxxxxxx_status_flag
attribute nitrogen_in_nitrate_processed_corrected_mg_n_per_l_flags units String none
variable absorbance_254_raw_unitless   float  
attribute absorbance_254_raw_unitless ioos_category String Other
attribute absorbance_254_raw_unitless sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute absorbance_254_raw_unitless standard_name String absp254a
variable absorbance_254_raw_unitless_flags   String  
attribute absorbance_254_raw_unitless_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute absorbance_254_raw_unitless_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute absorbance_254_raw_unitless_flags ioos_category String Other
attribute absorbance_254_raw_unitless_flags standard_name String absp254a_status_flag
attribute absorbance_254_raw_unitless_flags units String none
variable absorbance_350_raw_unitless   float  
attribute absorbance_350_raw_unitless ioos_category String Other
attribute absorbance_350_raw_unitless sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute absorbance_350_raw_unitless standard_name String absp350a
variable absorbance_350_raw_unitless_flags   String  
attribute absorbance_350_raw_unitless_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute absorbance_350_raw_unitless_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute absorbance_350_raw_unitless_flags ioos_category String Other
attribute absorbance_350_raw_unitless_flags standard_name String absp350a_status_flag
attribute absorbance_350_raw_unitless_flags units String none
variable bromide_internally_derived_mg_per_l   float  
attribute bromide_internally_derived_mg_per_l ioos_category String Dissolved Nutrients
attribute bromide_internally_derived_mg_per_l sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute bromide_internally_derived_mg_per_l standard_name String xxxxxxxx
attribute bromide_internally_derived_mg_per_l units String mg/l
variable bromide_internally_derived_mg_per_l_flags   String  
attribute bromide_internally_derived_mg_per_l_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute bromide_internally_derived_mg_per_l_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute bromide_internally_derived_mg_per_l_flags ioos_category String Dissolved Nutrients
attribute bromide_internally_derived_mg_per_l_flags standard_name String xxxxxxxx_status_flag
attribute bromide_internally_derived_mg_per_l_flags units String none
variable spectrometer_temperature_raw_degrees_c   float  
attribute spectrometer_temperature_raw_degrees_c ioos_category String Other
attribute spectrometer_temperature_raw_degrees_c sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute spectrometer_temperature_raw_degrees_c standard_name String xxxxxxxx
attribute spectrometer_temperature_raw_degrees_c units String degrees_C
variable spectrometer_temperature_raw_degrees_c_flags   String  
attribute spectrometer_temperature_raw_degrees_c_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute spectrometer_temperature_raw_degrees_c_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute spectrometer_temperature_raw_degrees_c_flags ioos_category String Other
attribute spectrometer_temperature_raw_degrees_c_flags standard_name String xxxxxxxx_status_flag
attribute spectrometer_temperature_raw_degrees_c_flags units String none
variable internal_temperature_raw_degrees_c   float  
attribute internal_temperature_raw_degrees_c ioos_category String Other
attribute internal_temperature_raw_degrees_c sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute internal_temperature_raw_degrees_c standard_name String xxxxxxxx
attribute internal_temperature_raw_degrees_c units String degrees_C
variable internal_temperature_raw_degrees_c_flags   String  
attribute internal_temperature_raw_degrees_c_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute internal_temperature_raw_degrees_c_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute internal_temperature_raw_degrees_c_flags ioos_category String Other
attribute internal_temperature_raw_degrees_c_flags standard_name String xxxxxxxx_status_flag
attribute internal_temperature_raw_degrees_c_flags units String none
variable lamp_temp_raw_degrees_c   float  
attribute lamp_temp_raw_degrees_c ioos_category String Other
attribute lamp_temp_raw_degrees_c sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute lamp_temp_raw_degrees_c standard_name String xxxxxxxx
attribute lamp_temp_raw_degrees_c units String degrees_C
variable lamp_temp_raw_degrees_c_flags   String  
attribute lamp_temp_raw_degrees_c_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute lamp_temp_raw_degrees_c_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute lamp_temp_raw_degrees_c_flags ioos_category String Other
attribute lamp_temp_raw_degrees_c_flags standard_name String xxxxxxxx_status_flag
attribute lamp_temp_raw_degrees_c_flags units String none
variable internal_relative_humidity_raw_percent   float  
attribute internal_relative_humidity_raw_percent ioos_category String Other
attribute internal_relative_humidity_raw_percent sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute internal_relative_humidity_raw_percent standard_name String xxxxxxxx
attribute internal_relative_humidity_raw_percent units String %
variable internal_relative_humidity_raw_percent_flags   String  
attribute internal_relative_humidity_raw_percent_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute internal_relative_humidity_raw_percent_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute internal_relative_humidity_raw_percent_flags ioos_category String Other
attribute internal_relative_humidity_raw_percent_flags standard_name String xxxxxxxx_status_flag
attribute internal_relative_humidity_raw_percent_flags units String none
variable main_voltage_raw_v   double  
attribute main_voltage_raw_v ioos_category String Other
attribute main_voltage_raw_v sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute main_voltage_raw_v standard_name String xxxxxxxx
attribute main_voltage_raw_v units String V
variable main_voltage_raw_v_flags   String  
attribute main_voltage_raw_v_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute main_voltage_raw_v_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute main_voltage_raw_v_flags ioos_category String Other
attribute main_voltage_raw_v_flags standard_name String xxxxxxxx_status_flag
attribute main_voltage_raw_v_flags units String none
variable internal_voltage_raw_v   double  
attribute internal_voltage_raw_v ioos_category String Other
attribute internal_voltage_raw_v sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute internal_voltage_raw_v standard_name String xxxxxxxx
attribute internal_voltage_raw_v units String V
variable internal_voltage_raw_v_flags   String  
attribute internal_voltage_raw_v_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute internal_voltage_raw_v_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute internal_voltage_raw_v_flags ioos_category String Other
attribute internal_voltage_raw_v_flags standard_name String xxxxxxxx_status_flag
attribute internal_voltage_raw_v_flags units String none
variable lamp_voltage_raw_v   double  
attribute lamp_voltage_raw_v ioos_category String Other
attribute lamp_voltage_raw_v sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute lamp_voltage_raw_v standard_name String xxxxxxxx
attribute lamp_voltage_raw_v units String V
variable lamp_voltage_raw_v_flags   String  
attribute lamp_voltage_raw_v_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute lamp_voltage_raw_v_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute lamp_voltage_raw_v_flags ioos_category String Other
attribute lamp_voltage_raw_v_flags standard_name String xxxxxxxx_status_flag
attribute lamp_voltage_raw_v_flags units String none
variable dark_value_raw_counts   double  
attribute dark_value_raw_counts ioos_category String Dissolved Nutrients
attribute dark_value_raw_counts sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute dark_value_raw_counts standard_name String xxxxxx
attribute dark_value_raw_counts units String counts
variable dark_value_raw_counts_flags   String  
attribute dark_value_raw_counts_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute dark_value_raw_counts_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute dark_value_raw_counts_flags ioos_category String Dissolved Nutrients
attribute dark_value_raw_counts_flags standard_name String xxxxxx_status_flag
attribute dark_value_raw_counts_flags units String none
variable cumulative_lamp_time_raw_s   double  
attribute cumulative_lamp_time_raw_s ioos_category String Unknown
attribute cumulative_lamp_time_raw_s sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute cumulative_lamp_time_raw_s standard_name String xxxxxxxx
attribute cumulative_lamp_time_raw_s units String s
variable cumulative_lamp_time_raw_s_flags   String  
attribute cumulative_lamp_time_raw_s_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute cumulative_lamp_time_raw_s_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute cumulative_lamp_time_raw_s_flags ioos_category String Unknown
attribute cumulative_lamp_time_raw_s_flags standard_name String xxxxxxxx_status_flag
attribute cumulative_lamp_time_raw_s_flags units String none
variable main_current_raw_ma   double  
attribute main_current_raw_ma ioos_category String Other
attribute main_current_raw_ma sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute main_current_raw_ma standard_name String xxxxxxxx
attribute main_current_raw_ma units String mA
variable main_current_raw_ma_flags   String  
attribute main_current_raw_ma_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute main_current_raw_ma_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute main_current_raw_ma_flags ioos_category String Other
attribute main_current_raw_ma_flags standard_name String xxxxxxxx_status_flag
attribute main_current_raw_ma_flags units String none
variable asm_raw_counts   String  
attribute asm_raw_counts ioos_category String Dissolved Nutrients
attribute asm_raw_counts sensor_description String SUNA V2 : Sea-Bird Scientific (Sea-Bird Electronics) Satlantic Submersible Ultraviolet Nitrate Analyser V2 {SUNA V2} nutrient analyser series NTR-2094 : Main Lab
attribute asm_raw_counts standard_name String uvinzz01
attribute asm_raw_counts units String counts
variable asm_raw_counts_flags   String  
attribute asm_raw_counts_flags flag_notes String Flags of value 0: the QC test was not applicable. Flags of value 1: passed the QC test. Flags of value 2: quality was not evaluated or is unknown. Flags of value 3: quality is questionable/suspect or data are of high interest. Flags of value 4: failed the QC test. Flags of value 9: data are missing.
attribute asm_raw_counts_flags flag_order String 0:Gap Test, 1:Syntax Test, 2:Gross Range Test, 3:Global Range Test, 4:Local Range Test, 5:Sensor Status Test, 6:Pump On Flag, 7:Port Status Test, 8:Filter Blank Flag, 9:Derived Data Time Check, 10:Unused, 11:Unused, 12:Unused, 13:Unused, 14:Unused, 15:Unused, 16:Unused, 17:Unused, 18:Unused, 19:Unused, 20:Unused, 21:Unused, 22:Unused, 23:Unused, 24:Unused, 25:Unused, 26:Unused, 27:Unused, 28:Unused, 29:Unused,
attribute asm_raw_counts_flags ioos_category String Dissolved Nutrients
attribute asm_raw_counts_flags standard_name String uvinzz01_status_flag
attribute asm_raw_counts_flags units String none

The information in the table above is also available in other file formats (.csv, .htmlTable, .itx, .json, .jsonlCSV1, .jsonlCSV, .jsonlKVP, .mat, .nc, .nccsv, .tsv, .xhtml) via a RESTful web service.


 
ERDDAP, Version 2.23
Disclaimers | Privacy Policy | Contact